Blast-Resistant Solutions

Double-Leaf Door

Doors for wide openings, equipment passage and high-traffic industrial areas. The double-leaf mechanism distributes the load evenly and resists high explosion pressures while staying easy to operate.

Double-Leaf Door 1
Double-Leaf Door 1
Double-Leaf Door 2
Double-Leaf Door 2

How it works

A double-leaf blast door has two door leaves that close on a common frame and lock together, which spreads the blast load across both leaves and the frame. It is used where one leaf would be too wide or heavy, or where equipment must pass. As with every blast door, the wall and anchors must be designed for the same load.

Typical applications

  • Equipment passage into process buildings
  • Wide openings in protected rooms
  • High-traffic industrial entrances

Product range data

Values are indicative. Final values are set per project through engineering analysis, test reports and certificates. The standards named are a reference framework, not a certification claim.

  • Design blast load: from 0.1 bar up to 45 bar and above, set per project
  • Opening direction: inward or outward
  • Optional fire resistance: EI60, EI90 or EI120
  • Optional ballistic protection: EN 1522 FB4 to FB7
  • Optional forced-entry resistance: RC3 to RC5
  • Optional gas tightness (CBRN)
  • Materials: S235JR or S355JR structural steel, or stainless steel
  • Surface protection: epoxy primer with polyurethane topcoat
  • Multi-point locking, heavy-duty ball-bearing hinges and a high-performance sealing gasket
  • Optional equipment: panic bar, hydraulic door closer, vision panel, card access control, door status sensor, pressure equalising vent

Key points when specifying

  • Clear opening and the sizes of equipment or vehicles that must pass
  • Design blast load, impulse and direction
  • How the two leaves lock to each other and to the frame
  • Whether one leaf may be used alone for personnel

Standards and guidance commonly referenced for this product type

  • ASTM F2247
  • ASTM F2927
  • EN 13123-1
  • EN 13124-1
  • UFC 3-340-02

These are general references. Compliance and test reports for a specific product are provided per project.

Why choose a double-leaf door over a single-leaf door?

Choose a double-leaf door when the opening is too wide for one leaf to be practical, or when equipment has to pass through. Two smaller leaves are easier to handle and operate than one very large leaf. The extra leaf needs careful sealing and locking at the meeting edge.

Is a double-leaf blast door weaker than a single-leaf door?

Not if it is designed for it. The two leaves, the centre joint and the locking are engineered as one system for the blast load. The centre joint and the locking are the points that need particular attention in the design.

Technical specifications, protection levels and test reports are provided per project. Contact our engineers for details.

Planning a protected facility?

Tell us about your site, threat scenario and timeline. Our engineers will respond with the right solution.