Blast-Resistant Solutions

Single-Leaf Door

Doors for limited spaces such as industrial facilities and control rooms. The compact design allows fast access, and the high-strength body forms a safe barrier against explosion pressure.

Single-Leaf Door 1
Single-Leaf Door 1
Single-Leaf Door 2
Single-Leaf Door 2
Single-Leaf Door 3
Single-Leaf Door 3
Single-Leaf Door 4
Single-Leaf Door 4

How it works

A blast door is built so that the door leaf, frame, hinges and locks together carry the pressure and impulse of an explosion without failing or letting the load into the room. It is anchored in a wall designed for the same load, and its design is based on a defined threat, such as the charge size and distance. A single-leaf door suits personnel openings.

Typical applications

  • Control rooms and equipment rooms
  • Process buildings and laboratories
  • Entrances of protective shelters

Product range data

Values are indicative. Final values are set per project through engineering analysis, test reports and certificates. The standards named are a reference framework, not a certification claim.

  • Design blast load: from 0.1 bar up to 45 bar and above, set per project
  • Opening direction: inward or outward
  • Optional fire resistance: EI60, EI90 or EI120
  • Optional ballistic protection: EN 1522 FB4 to FB7
  • Optional forced-entry resistance: RC3 to RC5
  • Optional gas tightness (CBRN)
  • Materials: S235JR or S355JR structural steel, or stainless steel
  • Surface protection: epoxy primer with polyurethane topcoat
  • Multi-point locking, heavy-duty ball-bearing hinges and a high-performance sealing gasket
  • Optional equipment: panic bar, hydraulic door closer, vision panel, card access control, door status sensor, pressure equalising vent

Key points when specifying

  • Clear opening and which way the door opens relative to the blast
  • Design pressure and impulse, and the acceptable deformation
  • Frame and wall type, and the anchoring to the structure
  • Extra functions: fire rating, gas tightness, ballistic resistance or access control

Standards and guidance commonly referenced for this product type

  • ASTM F2247
  • ASTM F2927
  • EN 13123-1
  • EN 13124-1
  • UFC 3-340-02

These are general references. Compliance and test reports for a specific product are provided per project.

What does a manufacturer need to size a blast door?

The design blast load (peak pressure and impulse, or the charge and distance), the direction the load acts from, the opening size, the wall type and any extra needs such as fire rating, gas tightness or ballistic resistance. Operating details, such as swing direction and locking, are also needed.

Can a single-leaf blast door be used as an emergency exit?

Yes, if it is specified for it. Panic hardware and a safe opening force can be included, and the required escape function has to be considered together with the blast and security locking so that one does not defeat the other.

Technical specifications, protection levels and test reports are provided per project. Contact our engineers for details.

Planning a protected facility?

Tell us about your site, threat scenario and timeline. Our engineers will respond with the right solution.